SIMULATION MODE
Disaster response control room

One network. One response.

Monitor the mesh, test virtual sensors and calculate emergency routes from one workspace.

--:--:--LOCAL SYSTEM TIME
SYSTEM NORMAL
All monitored values are within configured limits. The mesh network is ready.
0ACTIVE SENSOR ALERTS
Nodes online ⌘
23/23Network availability
Active incidents ◉
0Detected at virtual nodes
Route status ↗
READYAwaiting emergency event
Sensors monitored ⌁
05Virtual sensor channels
01 /MESH NETWORK MAP
Click a house to select its source. Click HOS, POL or FIRE to choose a response destination. Clicking never changes node availability.
23 NODES ONLINE
Online node Alert / offline Disconnected link Active BFS route
02 /RESPONSE SUMMARY
LIVE LOGIC
Network standing by

Select a house, run a sensor scenario or trigger a manual SOS to see how PULSE responds.

SHORTEST AVAILABLE ROUTE · BFS
No route calculated
Destination: HOS · Hospital
H1 · House 1Selected source node · Ready
ONLINE
03 /NETWORK NOTES
The route engine uses Breadth-First Search (BFS) to find the shortest available path from the selected house to the chosen response facility (hospital, police station or fire station). Offline nodes are excluded from traversal. If the source, destination or a required path is unavailable, delivery is marked failed.
23 NETWORK NODESUNDIRECTED LINKSLOCAL BFS
04 /SENSOR TELEMETRY
Virtual readings assigned to the selected source node.
SOURCE: H1
Fire intensity🔥
8 %
Alert ≥ 60%
● NORMAL
Temperature🌡
29 °C
Alert ≥ 55°C
● NORMAL
Vibration〰
1.2 units
Alert ≥ 8 units
● NORMAL
Water level💧
12 %
Alert ≥ 60%
● NORMAL
Ultrasonic distance📡
120 cm
Alert ≤ 25 cm
● NORMAL
05 /SCENARIO SIMULATOR
Load an event profile, then run sensor detection and network response.
LOCAL SIMULATION
DETECTION EXPLANATION

Choose an event profile or adjust the manual controls. PULSE will check thresholds and, when a hazard is detected, attempt to route an SOS to the selected facility.

06 /MANUAL SENSOR TEST
Adjust individual virtual sensor values.
8%
Alert threshold: 60%
29°C
Alert threshold: 55°C
1.2 units
Alert threshold: 8 units
12%
Alert threshold: 60%
120 cm
Alert threshold: 25 cm or below
07 /EVENT TIMELINE
Detection, route and network-state events.
0 EVENTS
No events recorded yet. The system is standing by.
▣
PHYSICAL NODE · ESP32Hardware integration status is shown separately from this browser simulation.
DS18B20 TEMPERATUREFIRE SENSORVIBRATION SENSORULTRASONICWATER · VIRTUAL CHANNEL
● NOT CONNECTED TO BROWSER